CEN and CENELEC ratified CRA standards EN 40000-1-1 and EN 40000-1-2 on 2 November 2026, with the texts available from 18 November 2026. They are the first standards under the Cyber Resilience Act to reach publication, drafted by CEN/CENELEC JTC 13 under Commission standardisation request M/606. EN 40000-1-1 is the vocabulary. EN 40000-1-2 covers cybersecurity principles, product risk management and lifecycle activities, mapping to Annex I Part I of the CRA and the risk assessment duty in Article 13. The detail that most coverage has skipped is the one that matters commercially. CEN project records mark EN 40000-1-2 as no citation expected under the CRA. A standard not cited in the Official Journal carries no presumption of conformity under Article 27. As at 19 November 2026, publication of references to either standard in the Official Journal had not been confirmed. The standard a manufacturer should be watching is prEN 40000-1-3 on vulnerability handling, which maps to Annex I Part II and is marked citation expected. It entered formal vote in November 2026. CRA full application is 11 December 2027. Reporting obligations under Article 14 have already applied since 11 September 2026. Official text: Regulation (EU) 2024/2847 Key Definitions to Know TermDefinitionCRACyber Resilience Act, Regulation (EU) 2024/2847. Horizontal cybersecurity requirements for products with digital elements placed on the EU marketM/606The European Commission’s standardisation request to CEN, CENELEC and ETSI in support of the CRA, accepted in April 2025, covering 41 harmonised standardsCEN/CENELEC JTC 13The joint technical committee responsible for cybersecurity and data protection standardisation, drafting the EN 40000 seriesHorizontal standardA standard applying across all products in scope rather than to a single product categoryVertical standardA standard addressing a specific product categoryHarmonised standardA European standard cited in the Official Journal in support of Union legislation, carrying presumption of conformityPresumption of conformityUnder Article 27 CRA, a product conforming to a cited harmonised standard is presumed to comply with the essential requirements that standard coversAnnex I Part IThe essential cybersecurity requirements for the properties of products with digital elementsAnnex I Part IIThe vulnerability handling requirementsRatificationThe CEN-CENELEC step confirming a standard has passed formal vote and setting the date its text becomes availableFprENFinal draft European Standard, the stage immediately before publicationprENDraft European Standard, still in development or enquiry CRA Standards: What Was Published StandardFull titleStatusEN 40000-1-1:2026Cybersecurity requirements for products with digital elements — Part 1-1: VocabularyRatified 2 November 2026, text available 18 November 2026EN 40000-1-2:2026Cybersecurity requirements for products with digital elements — Part 1-2: Principles, product risk management, and lifecycle activitiesRatified 2 November 2026, text available 18 November 2026 EN 40000-1-1 does what vocabulary standards do. It defines the terms the rest of the series uses, which matters more than it sounds: a horizontal series spanning 41 standards and dozens of product categories fails without shared definitions. EN 40000-1-2 is the substantive one. Its scope statement: “This document specifies general cybersecurity principles and general risk management activities for all products with digital elements.” It covers the risk management methodology and the lifecycle activities sitting behind the Annex I Part I product requirements. Article 13(1) of the CRA obliges manufacturers to ensure a product with digital elements has been designed, developed and produced in accordance with the essential requirements in Annex I Part I. Article 13(2) requires a cybersecurity risk assessment. EN 40000-1-2 is the methodology for the second, feeding the first. Note that the title changed during drafting. The October 2025 draft was Principles for cyber resilience. The published standard is Principles, product risk management, and lifecycle activities, which is a more accurate description of what it contains. The Citation Problem This is the part of the story that has been reported thinly, and it changes what a manufacturer should do with the standard. Publication and citation are different events. Article 27(1) of the CRA provides that products with digital elements, and processes put in place by the manufacturer, which are in conformity with harmonised standards or parts thereof the references of which have been published in the Official Journal, are presumed to be in conformity with the essential requirements covered by those standards. The operative words are the references of which have been published in the Official Journal. A standard that exists, has been ratified, and is available for purchase carries no legal presumption until that step happens. StandardCitation statusEN 40000-1-1Vocabulary. Supporting document. Citation not the mechanism by which it operatesEN 40000-1-2CEN project records mark it no citation expected under the CRAprEN 40000-1-3Marked citation expected. Reported as the first horizontal part likely to be citedprEN 40000-1-4CEN expects no Official Journal citation As at 19 November 2026, publication of references to EN 40000-1-1 and EN 40000-1-2 in the Official Journal had not been confirmed. The practical consequence is specific. A manufacturer implementing EN 40000-1-2 gets a well-constructed risk management methodology that CEN/CENELEC JTC 13 built against the CRA’s requirements. It does not get presumption of conformity with Annex I Part I. Compliance with Annex I still has to be demonstrated on its own terms, and the standard is evidence of a sound approach rather than a legal shortcut. That is not a reason to ignore it. It is a reason not to tell your board that the standards problem is solved. The Full EN 40000 Horisontal Series PartSubjectCRA mappingM/606 itemStatus as at 19 November 2026EN 40000-1-1VocabularySupporting terminologySupportingPublished. Text available 18 November 2026EN 40000-1-2Principles, product risk management, lifecycle activitiesAnnex I Part I(1), Article 13 risk assessment1Published. No citation expectedprEN 40000-1-3Vulnerability handlingAnnex I Part II15Entered formal vote November 2026. Citation expectedprEN 40000-1-4Generic security requirements, technical controlsAnnex I Part I(2), points (a) to (m)2 to 14Under drafting at CEN as work item JT013091. No EN number yet. Delivery date given as 30 October 2027. No citation expected The series is horizontal, meaning each part applies across all products with digital elements rather than to a single category. Vertical standards covering specific product categories sit alongside it. Part 1-4 is the one with the longest tail and the widest reach. It is the catalogue of technical security requirement areas mapping to the Annex I Part I(2) essential requirements, points (a) through (m). A delivery date of 30 October 2027 puts it roughly six weeks ahead of CRA full application, which is not a comfortable margin for anyone planning to build against it. Why prEN 40000-1-3 Is the One CRA Standard to Watch Part 1-3 covers vulnerability handling, mapping to Annex I Part II. That is the set of obligations a manufacturer must meet throughout the support period: identifying and documenting components including an SBOM, addressing vulnerabilities without delay, applying effective and regular tests, publicly disclosing fixed vulnerabilities, having a coordinated vulnerability disclosure policy, facilitating information sharing, providing mechanisms for secure distribution of updates, and disseminating security patches without delay and free of charge. It is also the part marked citation expected, which makes it the first horizontal standard likely to carry presumption of conformity. The timing matters. Article 14 reporting obligations have applied since 11 September 2026, requiring notification of actively exploited vulnerabilities within 24 hours through ENISA’s Single Reporting Platform. A manufacturer is already operating under the vulnerability reporting duty while the standard that will define good practice for the underlying handling process is still in formal vote. How These CRA Standards Sit in the Entire CRA Timeline DateEvent10 December 2024CRA enters into forceApril 2025M/606 accepted by CEN, CENELEC and ETSI. 41 standards in scope11 June 2026Chapter IV applies. Member states designate notifying authorities and notified bodies11 September 2026Article 14 reporting obligations apply. Single Reporting Platform live2 November 2026CEN ratifies EN 40000-1-1 and EN 40000-1-218 November 2026Texts of EN 40000-1-1 and EN 40000-1-2 become availableNovember 2026prEN 40000-1-3 enters formal vote30 October 2027Delivery date given for prEN 40000-1-411 December 2027CRA full application. Annex I, SBOM, technical documentation, CE marking, conformity assessment Thirteen months remain to full application. Two horizontal standards exist, neither carrying presumption of conformity. The standard covering the technical control catalogue is due six weeks before the deadline. Manufacturers waiting for the standards framework to settle before beginning work have, on the current schedule, no runway at all. The AI Act Bridge One interaction is worth naming because it produces a genuine efficiency rather than a duplication. Where a product with digital elements is also a high-risk AI system under Article 6 of the AI Act, satisfying the CRA’s essential cybersecurity requirements in Annex I Parts I and II deems the product compliant with the AI Act’s cybersecurity requirements under Article 15. That is substitution rather than alignment. The exception runs the other way for higher-risk categories. For products classified as important under CRA Annex III or critical under CRA Annex IV, CRA assessment procedures take precedence on cybersecurity aspects, even where the AI Act’s internal control procedure would otherwise apply. Product situationCybersecurity governed byOther AI Act requirementsHigh-risk AI system, CRA default classCRA Annex I satisfies AI Act Article 15AI Act internal control procedureHigh-risk AI system, CRA Annex III importantCRA assessment procedures take precedenceAI Act internal control procedure for accuracy, robustness, transparency, human oversightHigh-risk AI system, CRA Annex IV critical, European cybersecurity certificate requiredCRA procedures governAI Act internal control procedure for all other requirements A manufacturer shipping an AI-enabled connected product is therefore running two conformity assessments with one shared cybersecurity determination, and which instrument governs that determination depends on the CRA product class rather than the AI Act risk tier. Where CRA Standards Compare to the AI Act Standards Track The CRA standards position is roughly twelve months behind the AI Act’s. FrameworkFirst standardCitation statusFull applicationEU AI ActEN 18286:2026, QMS for Article 17Cited in the Official Journal 14 October 2026. Presumption of conformity attaches2 December 2027 (Annex III)CRAEN 40000-1-1 and EN 40000-1-2Published 18 November 2026. Citation not confirmed. 1-2 marked no citation expected11 December 2027 EN 18286 took the full route: approval in July 2026, citation in October 2026, presumption of conformity from that date. The EN 40000 series has reached the first step without the second, and CEN’s own project records indicate that for Parts 1-2 and 1-4 the second step is not planned. That is a structural difference rather than a delay. The CRA’s horizontal series is being built with only some parts intended to carry presumption of conformity, which means manufacturers cannot treat implementation of the series as a route to deemed compliance across Annex I. What Manufacturers Should Do Now About CRA Standards StepAction1Confirm whether each product is a product with digital elements, and determine its class: default, important Annex III, or critical Annex IV2Obtain EN 40000-1-1 and EN 40000-1-2 from your national standards body3Build the Article 13(2) cybersecurity risk assessment methodology against EN 40000-1-2, documenting that the standard is not cited and that Annex I compliance is demonstrated independently4Track prEN 40000-1-3 through formal vote. It is the vulnerability handling standard and the one expected to be cited5Do not wait for prEN 40000-1-4. Build the Annex I Part I(2) technical controls against the regulation text, since the standard is due six weeks before full application6Confirm Article 14 reporting is operational. It has been in force since 11 September 2026 and covers products already on the market7Generate an SBOM in a machine-readable format covering at least top-level dependencies, and preferably the full transitive tree8Define and publish the support period, minimum five years as a rule, visible at the point of sale9Establish the coordinated vulnerability disclosure policy required by Annex I Part II10Identify your conformity assessment route and engage a notified body early where Annex III class II or Annex IV applies11Where the product is also a high-risk AI system, map the Article 15 substitution and determine which instrument governs the cybersecurity assessment Step 3 is the one that separates a defensible position from a comfortable one. Implementing a standard that carries no presumption of conformity is sound engineering practice and does not relieve the manufacturer of demonstrating Annex I compliance directly Where Grecta Fits Grecta turns EU product law into engineering tickets, release gates and a public verification page your buyers can check. The EN 40000 position illustrates the problem precisely. Two standards published, one marked no citation expected, one in formal vote, one due six weeks before the deadline, and an AI Act bridge whose direction depends on the CRA product class. That is not a question a quarterly compliance review answers. It changes with each ratification, each citation, and each product change. Grecta resolves every obligation that fires for a specific product across 26 EU frameworks, article by article, deterministically, with the clause behind every answer. It settles the classification, the legal role and whether anything is banned outright. It writes the gaps into the engineering backlog against the article that requires them. It clears or blocks every release in sixty seconds before it ships. It tells a product owner, before the code is written, what a planned change would trigger. It prices the exposure for the CFO. It issues the product a live verification page buyers can open, and holds immutable snapshots behind it. For the CRA specifically, that means the Annex I determination is computed against the regulation rather than inferred from a standard that may never be cited, the SBOM and support period obligations sit in the backlog with deadlines attached, and when prEN 40000-1-3 is cited the position updates without anyone rerunning the exercise by hand. Request a demo to see which CRA and AI Act obligations reach your product, and what the gap looks like against the 11 December 2027 deadline. Frequently Asked Questions What is EN 40000? The horizontal series of European standards supporting the EU Cyber Resilience Act, drafted by CEN/CENELEC JTC 13 under Commission standardisation request M/606. The series applies across all products with digital elements rather than to a single product category. What do EN 40000-1-1 and EN 40000-1-2 cover? EN 40000-1-1 is the vocabulary, defining terms used across the series. EN 40000-1-2 covers cybersecurity principles, product risk management and lifecycle activities, mapping to Annex I Part I of the CRA and the Article 13 risk assessment duty. When were the first CRA standards published? CEN ratified EN 40000-1-1 and EN 40000-1-2 on 2 November 2026, with the texts available from 18 November 2026. They are the first standards under the CRA to reach publication. Does EN 40000-1-2 give presumption of conformity with the CRA? No, not on current indications. CEN project records mark EN 40000-1-2 as no citation expected under the CRA, and as at 19 November 2026 publication of its reference in the Official Journal had not been confirmed. Presumption of conformity under Article 27 attaches only once a standard’s reference is published in the Official Journal. Which EN 40000 part covers vulnerability handling? prEN 40000-1-3, mapping to Annex I Part II of the CRA. It entered formal vote in November 2026 and is marked citation expected, which makes it the first horizontal part likely to carry presumption of conformity. What is prEN 40000-1-4? The generic security requirements standard, covering the catalogue of technical security requirement areas mapping to Annex I Part I(2) points (a) to (m). It is under drafting at CEN as work item JT013091 with no EN number yet, and a delivery date given as 30 October 2027. CEN expects no Official Journal citation. How many CRA standards are there in total? Mandate M/606 covers 41 harmonised standards organised in a Type A, B and C hierarchy of framework, horizontal and vertical standards. The EN 40000 series is the horizontal set. Vertical standards address specific product categories. Should we implement EN 40000-1-2 if it will not be cited? Implementing it gives a risk management methodology built against the CRA by the committee drafting the series, which is sound practice and useful evidence of a considered approach. It does not produce presumption of conformity, so Annex I compliance must still be demonstrated independently and the documentation should say so. When does the CRA apply in full? 11 December 2027 for the essential requirements, SBOM, technical documentation, CE marking and conformity assessment. Article 14 reporting obligations have applied since 11 September 2026 and cover products already on the market. Does CRA compliance satisfy the EU AI Act’s cybersecurity requirement? For a product with digital elements that is also a high-risk AI system, satisfying the CRA’s essential requirements in Annex I Parts I and II deems the product compliant with AI Act Article 15. For products classified as important under CRA Annex III or critical under Annex IV, CRA assessment procedures take precedence on cybersecurity aspects. All other AI Act requirements remain under the AI Act. Do non-EU manufacturers need to apply EN 40000? The CRA applies to any manufacturer placing a product with digital elements on the EU market regardless of establishment. The standards are voluntary in the same way for everyone. A UK, US or Swiss manufacturer faces the same Annex I obligations and the same question about which standards carry presumption of conformity. Where do we obtain the standards? Through your national standards body. National adoptions appear under local prefixes, for example DIN EN 40000-1-2 in Germany, BS EN 40000-1-2 in the UK and SIST EN 40000-1-2 in Slovenia. The technical content is identical. Sources Regulation (EU) 2024/2847, Cyber Resilience Act CEN-CENELEC, cybersecurity standardisation European Commission, Cyber Resilience Act EN 40000-1-2:2026 catalogue entry ENISA, Single Reporting Platform This guide reflects the status of the EN 40000 series as at 19 November 2026. Citation status is drawn from CEN project records and may change. Publication of references in the Official Journal of the European Union is the determinative step for presumption of conformity under Article 27 CRA, and should be verified directly before relying on any standard for that purpose. Published by Grecta. It is regulatory analysis, not legal advice.
Mar 12, 2026 EU AI Act for Small Businesses A practical legal guide for SMEs navigating Regulation (EU) 2024/1689. Read more
Apr 29, 2026 NIST AI RMF and the EU AI Act How the voluntary US framework relates to the binding EU regulation — where the two align on substantive... Read more
Nov 5, 2026 Product update: Article 5 check at the start of intake EU AI Act intake in Grecta now opens with five yes/no questions that screen a product against Article... Read more